3
© 2008 - 2011 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO2020C/2330C/2820C/2830C/3520C/3530C/4520C
ADJUSTMENT
3 - 63
3.5.2 Beam level conversion setting
A beam level for smoothing process (divided into 4) in the fax function can be set. In this setting the size
of dots is adjusted.
<Adjustment Mode (05)>
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON.
(2) Key in a code and press the [START] button.
(3) Key in a sub-code and press the [START] button.
(4) Key in an adjustment value.
(To correct a value once keyed in, press the [CLEAR] button.)
(5) Press the [ENTER] or [INTERRUPT] button to store the value. → The equipment goes back to
the ready state.
(6) Take the POWER OFF.
<Confirmation>
Check the beam level conversion setting with the actual fax data received, if possible.
1. The setting value must increase as the beam level number (0 to 4) becomes higher. Do not
increase this order when setting the values.
2. Usually, beam level 4 / 4 is most effective on black mode.
Code Item to be adjusted Remarks
678-0 Beam level 0/4 The smaller the value is, the smaller the beam width
becomes. Therefore, the smaller dot is reproduced
accordingly. Acceptable values: 0 to 255
(Default: Level 0/4: 0, Level 1/4: 63, Level 2/4: 127,
Level 3/4: 191, Level 4/4: 255)
678-1 Beam level 1/4
678-2 Beam level 2/4
678-3 Beam level 3/4
678-4 Beam level 4/4