DISASSEMBLY AND REPLACEMENT
4 - 62
4.7.23 Doctor blade <23LA/23LM/28LM/23HA/28HA>
4.7.24 Mixer <20L/23L/25L/20H/23H/25H>
(1) Remove the developer material.
P. 4-59 "4.7.19 Removing developer
material"
(2) Remove 1 spring [1] and 1 screw [2], and
then take off the doctor blade [3].
Fig. 4-160
(1) Remove the developer material.
P. 4-59 "4.7.19 Removing developer
material"
(2) Remove 1 screw and take off the polarity
adjustment lever [1].
Notes:
Make a note of the position where the
polarity adjustment lever is pointing. (Mark
the position if needed.) When reassembling,
match the polarity adjustment lever with the
previously marked position on the scale.
Fig. 4-161
(3) Release 1 latch and take off the recovered
toner supply unit [2].
Fig. 4-162
[3]
[1]
[2]
[1]
[2]