6
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
SETTING / ADJUSTMENT
6 - 21
[G] Right margin
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON. (Adjustment Mode)
(2) Open the original cover or RADF.
(3) [SETTINGS] Set the density to the largest value and the original mode to Text.
(4) [USER FUNCTIONS] Select [DRAWER] Select [DRAWER1] Set the paper size to A3/LD.
[OK] Set A3/LD for the paper in upper drawer.
(5) [CANCEL] [CANCEL] Select the upper drawer by pressing [DRAWER]. Press [START]
to make copies.
(6) Measure the blank area G at the right side of the copied image.
(7) Check if the blank area G is within the range of 2±1.0 mm.
(8) If not, use the following procedure to change values and measure the distance G again.
[SETTINGS] (Key in the code [4052]) [START]
(Key in a value (acceptable values: 0 to 255))
[OK] (Stored in memory)
[SETTINGS] Select the upper drawer by pressing [DRAWER]. Press [START] to make
copies.
* The larger the adjustment value is, the wider the blank area at the right side becomes
(approx. 0.04 mm/step).