11
March 2005 © TOSHIBA TEC e-STUDIO520/600/720/850 DRUM/CLEANER UNIT
11 - 9
[C] Cleaning blade
[D] Recovery blade
(1) Take off the drum.
( P.11-7 "[B] Drum thermistor (THM5) and
Drum")
(2) Remove 4 screws to take off the cleaner top
cover.
Fig.11-12
(3) Remove 1 screw to take off the cleaning
blade by holding both sides of the plate.
Note:
Do not touch the edge of the cleaning blade.
Fig.11-13
(1) Take off the cleaning blade.
( P.11-9 "[C] Cleaning blade")
(2) Separate the recovery blade gently.
Fig.11-14
Cleaner top cover
Screw
Screw
Cleaning blade
Screw
Recovery blade