EasyManuals Logo

Toshiba GX9 User Manual

Toshiba GX9
270 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #151 background imageLoading...
Page #151 background image
GX9 ASD Installation and Operation Manual 139
Light-Load High-Speed Operation Heavy-Load Detection
Time
Program Special Crane/Hoist Load
While operating in the Light-Load High-Speed mode, this parameter
determines the length of time that a load exceeding the Light-Load High-
Speed operation criteria may exist before the Light-Load High-Speed mode is
terminated and normal operation resumes.
Direct Access Number — F334
Parameter Type — Numerical
Factory Default 5.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 10.0
Units — Seconds
Switching Load Torque During Forward-Run
Program Special Crane/Hoist Load
While running forward, this parameter establishes the threshold torque level
that is used to determine if the Light-Load High-Speed (F331) operation may
engage or remain engaged if active.
If the Light-Load High-Speed operation is terminated normal operation
resumes.
Direct Access Number — F335
Parameter Type — Numerical
Factory Default 50
Changeable During Run — Yes
Minimum — 0
Maximum — 250
Units — %
Heavy-Load Torque During Acceleration in the Forward
Direction
Program Special Crane/Hoist Load
During forward acceleration, this parameter establishes the threshold torque
level that is used to determine if the Light-Load High-Speed (F331) operation
may engage or remain engaged if active.
If the Light-Load High-Speed operation is terminated normal operation
resumes.
Direct Access Number — F336
Parameter Type — Numerical
Factory Default (ASD-Dependent)
Changeable During Run — Yes
Minimum — 0
Maximum — 250
Units — %
Heavy-Load Torque During Deceleration in the Forward
Direction
Program Special Crane/Hoist Load
During forward deceleration, this parameter establishes the threshold torque
level that is used to determine if the Light-Load High-Speed (F331) operation
may engage or remain engaged if active.
If the Light-Load High-Speed operation is terminated normal operation
resumes.
Direct Access Number — F337
Parameter Type — Numerical
Factory Default 100
Changeable During Run — Yes
Minimum — 0
Maximum — 250
Units — %
Switching Load Torque During Reverse-Run
Program Special Crane/Hoist Load
While running in reverse, this parameter establishes the threshold torque level
that is used to determine if the Light-Load High-Speed (F331) operation may
engage or remain engaged if active.
If the Light-Load High-Speed operation is terminated normal operation
resumes.
Direct Access Number — F338
Parameter Type — Numerical
Factory Default 50
Changeable During Run — Yes
Minimum — 0
Maximum — 250
Units — %
F334 F338

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba GX9 and is the answer not in the manual?

Toshiba GX9 Specifications

General IconGeneral
BrandToshiba
ModelGX9
CategoryController
LanguageEnglish

Related product manuals