EasyManuals Logo

Toshiba GX9 User Manual

Toshiba GX9
270 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #152 background imageLoading...
Page #152 background image
140 GX9 ASD Installation and Operation Manual
Heavy-Load Torque During Reverse Acceleration
Program Special Crane/Hoist Load
During reverse acceleration, this parameter establishes the threshold torque
level that is used to determine if the Light-Load High-Speed (F331) operation
may engage or remain engaged if active.
If the Light-Load High-Speed operation is terminated normal operation
resumes.
Direct Access Number — F339
Parameter Type — Numerical
Factory Default (ASD-Dependent)
Changeable During Run — Yes
Minimum — 0
Maximum — 250
Units — %
Heavy-Load Torque During Deceleration in the Reverse
Direction
Program Special Crane/Hoist Load
During reverse deceleration, this parameter establishes the threshold torque
level that is used to determine if the Light-Load High-Speed (F331) operation
may engage or remain engaged if active.
If the Light-Load High-Speed operation is terminated normal operation
resumes.
Direct Access Number — F340
Parameter Type — Numerical
Factory Default 100
Changeable During Run — Yes
Minimum — 0
Maximum — 250
Units — %
Frequency for Automatic High-Speed Operation at Light-
Load
Program Special Crane/Hoist Load
This parameter establishes the speed that the ASD will ramp to when operating
in the Light-Load High-Speed mode.
Direct Access Number — F341
Parameter Type — Numerical
Factory Default 80.0
Changeable During Run — Yes
Minimum — 30.0
Maximum — Upper Limit (F012)
Units — Hz
F339 F341

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba GX9 and is the answer not in the manual?

Toshiba GX9 Specifications

General IconGeneral
BrandToshiba
ModelGX9
CategoryController
LanguageEnglish

Related product manuals