156 GX9 ASD Installation and Operation Manual
Regenerative Braking Torque Limit 2 Level
Program Torque Manual Torque Limit Settings
This parameter is used to set the negative torque upper limit for the #2 motor
profile when multiple motors are controlled by a single drive or when a single
motor is to be controlled by multiple profiles.
Direct Access Number — F445
Parameter Type — Numerical
Factory Default 250.0 (Disabled)
Changeable During Run — Yes
Minimum — 0.00
Maximum — 250.0 (Disabled)
Units — %
Power Running Torque Limit 3 Level
Program Torque Manual Torque Limit Settings
This parameter is used to set the positive torque upper limit for the #3 motor
profile when multiple motors are controlled by a single drive or when a single
motor is to be controlled by multiple profiles.
Direct Access Number — F446
Parameter Type — Numerical
Factory Default 250.0 (Disabled)
Changeable During Run — Yes
Minimum — 0.00
Maximum — 250.0 (Disabled)
Units — %
Regenerative Braking Torque Limit 3 Level
Program Torque Manual Torque Limit Settings
This parameter is used to set the negative torque upper limit for the #3 motor
profile when multiple motors are controlled by a single drive or when a single
motor is to be controlled by multiple profiles.
Direct Access Number — F447
Parameter Type — Numerical
Factory Default 250.0 (Disabled)
Changeable During Run — Yes
Minimum — 0.00
Maximum — 250.0 (Disabled)
Units — %
Power Running Torque Limit 4 Level
Program Torque Manual Torque Limit Settings
This parameter is used to set the positive torque upper limit for the #4 motor
profile when multiple motors are controlled by a single drive or when a single
motor is to be controlled by multiple profiles.
Direct Access Number — F448
Parameter Type — Numerical
Factory Default 250.0 (Disabled)
Changeable During Run — Yes
Minimum — 0.00
Maximum — 250.0 (Disabled)
Units — %
Regenerative Braking Torque Limit 4 Level
Program Torque Manual Torque Limit Settings
This parameter is used to set the negative torque upper limit for the #4 motor
profile when multiple motors are controlled by a single drive or when a single
motor is to be controlled by multiple profiles.
Direct Access Number — F449
Parameter Type — Numerical
Factory Default 250.0 (Disabled)
Changeable During Run — Yes
Minimum — 0.00
Maximum — 250.0 (Disabled)
Units — %
Torque Limit Mode
Program Torque Torque Limit Settings
Contact Toshiba’s Marketing Department for information on this parameter.
Settings:
0 — Power Running/Regenerative Torque Limit
1 — Positive/Negative Torque Limits
Direct Access Number — F450
Parameter Type — Selection List
Factory Default Power Running/
Regenerative Torque Limit
Changeable During Run — No
F445 F450

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba GX9 and is the answer not in the manual?

Toshiba GX9 Specifications

General IconGeneral
BrandToshiba
ModelGX9
CategoryController
LanguageEnglish

Related product manuals