170 GX9 ASD Installation and Operation Manual
Pattern Run Disposition
Program Frequency Pattern Run
This parameter sets the start condition of subsequent Pattern Runs after the
initial Pattern Run has been terminated or has completed its programming.
Settings:
0 — Pattern Run Canceled After Stop
1 — Pattern Run Continued After Stop
Direct Access Number — F521
Parameter Type — Selection List
Factory Default Pattern Run
Canceled After Stop
Changeable During Run — No
Pattern Run Group 1 Repeat Factor
Program Frequency Pattern Run
This parameter sets the number of times that the pattern defined in Group 1
will be run.
Direct Access Number — F530
Parameter Type — Numerical
Factory Default 1
Changeable During Run — No
Minimum — 1
Maximum — 255 (Infinite)
Units — Repetitions
Pattern Run Group 1 Selection 1
Program Frequency Pattern Run
This parameter allows the user to select 1 of 15 configured Preset Speeds as
the number 1 selection to be included in the Group 1 Selection.
Skip may be selected to ignore this Selection.
Setting
0 — Skip
1 – 15 Preset Speed Number
Direct Access Number — F531
Parameter Type — Selection List
Factory Default Preset Speed 1
Changeable During Run — No
Pattern Run Group 1 Selection 2
Program Frequency Pattern Run
This parameter allows the user to select 1 of 15 configured Preset Speeds as
the number 2 selection to be included in the Group 1 Selection.
Skip may be selected to ignore this Selection.
Setting
0 — Skip
1 – 15 Preset Speed Number
Direct Access Number — F532
Parameter Type — Selection List
Factory Default Preset Speed 2
Changeable During Run — No
Pattern Run Group 1 Selection 3
Program Frequency Pattern Run
This parameter allows the user to select 1 of 15 configured Preset Speeds as
the number 3 selection to be included in the Group 1 Selection.
Skip may be selected to ignore this Selection.
Setting
0 — Skip
1 – 15 Preset Speed Number
Direct Access Number — F533
Parameter Type — Selection List
Factory Default Preset Speed 3
Changeable During Run — No
F521 F533