EasyManua.ls Logo

Toshiba nv Series - C.6 Analog Output Modules

Toshiba nv Series
177 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix A Base Unit BUM7B
6F8C1497
122
A
A.1.3 Power Supply Specifications
Table A.4 Power supply specifications
Item Specification Remarks
Rated voltage
100 - 120Vac, 200 - 240Vac
*1
Allowable voltage range 85 - 264Vac *1
Rated frequency 50/60Hz
Allowable frequency
range
47 - 53 / 57 - 63Hz
Allowable instantaneous
outage time
10ms or less
Allowable waveform
distortion factor
10% or less
Rated current
Max.1.5A (100 - 120Vac)
Max.0.75A (200 - 240Vac)
*2
Leak current Max. 2.0mA
Inrush current typ 14A (100Vac) / 28A (200Vac) *3
Output rating 5Vdc - 10A (for internal logic) *7
Insulation resistance
500Vdc Megger, 10Mohm or more (power input terminal -
FG)
Dielectric strength
voltage
2000Vac, one minute (power input terminal - FG)
Grounding Class D grounding (dedicated)
Protection circuit Overcurrent and overvoltage protection *4
Duplex power outlet None
Status display LED POWER *5
RUN contact Dry 1a contact (240Vac / 24Vdc - 2A max)
Switch None
Terminal block for
external lines
8-terminal, M3.5 screw (detachable)
*6
Overhaul
Replace the whole base unit at each of the target durable
years for the product
*1: Switching is not required for the 100Vac system and 200Vac system terminals.
*2: The rated current at the output rating (5Vdc - 10A) is typ.0.75A (100-120Vac), or typ.0.375A (200 -
240Vac).
*3: It is the value at the cold start with the ambient temperature of 25°C.
The inrush current may exceed the specification when the ambient temperature is high or immediately
after the operation.
*4: Remove the cause of error if the protection circuit starts operating.
Restarting the power supply may be required depending on the error.
*5: The LED (POWER) indicating the normal state of power is installed inside the unit. It cannot be seen
when a blank panel or terminal block signal conversion adapter is mounted.
*6: The terminal block is the same with the one used for PS361, suggesting that PS361 can be used without
any change.
*7: The maximum output current of the BUM7B power is 10A. Mount the I/O modules so that the total
consumption current of the I/O modules mounted on BUM7B does not exceed 10A.

Table of Contents