14 General Operation
128 Trimble R7/R8 GPS Receiver User Guide
Trimble R8 Operation
Table 14.2 shows approximate storage requirements for different
logging rates. The values shown are for a one-hour logging session
with six satellites visible.
145.2 Logging to a Trimble controller
When the Trimble R8 receiver is connected to a Trimble controller,
you can log GPS data from the receiver to the controller, or to a PC
card inserted in the controller. When you use a Trimble controller, you
do not use the receiver’s controls. Instead, you use the controller
functions to set logging options, specify filenames, and control when
logging occurs.
Data is stored in job files, which can be transferred to your office
computer using Trimble’s Data Transfer utility.
For more information on logging data from a receiver using a Trimble
controller refer to the user guide for your particular controller.
14.6 Resetting to Defaults
To reset the receiver to its factory default settings, hold down p for at
least 15 seconds.
For more information, see Default Settings, page 159.
Table 14.2 Storage requirements
Logging rate Memory required
10 Hz 2,588 KB
1Hz 335 KB
5 seconds 87 KB
15 seconds 37 KB