AWC708C PLUS Motion Control User Manual
WWW.SZTROCEN.COM
115
Table7-1 Mitsu MR-J3—A Series Basic Setting Parameters
Mode
Value
Instruction
PA01
0
Control mode: Position mode.
PA13
0011
Negative logic: Pulse + Direction.
Notice: The maximum pulse frequency of Mitsu J3 Series is 1Mpps.