TRUE ICE SERVICE MANUAL
TEC_TM_198 | REV. A | EN 03/26/2024 Page 17 of 96
truemfg.com
Ice Machine Specifications (cont.)
Electrical Requirements
Min. Circuit Ampacity & Max. Breaker/Fuse Size
Min./Max. Voltage Supply
NOTICE!
NOTE: Stinger, Wild or Hot legs should not be used in single phase application units. If present in a three-phase unit, it should
be wired so that the stinger or hot leg phase of voltage is fed directly to the compressor.
NOTE: It is not recommended to use a Ground Fault Circuit Interrupter (GFCI/GFI) receptacle with commercial equipment. If a
GFCI/GFI is required by code, use a GFCI/GFI breaker in the electrical panel, not an outlet, as outlet GFCI/GFI breakers are more
prone to intermittent nuisance trips than panel circuit breakers.
Min./Max. circuit ampacity & fuse size
Model Minimum Circuit
Ampacity
Maximum Overload Protection Breaker/fuse size
TCIM/TI-422 15 Amps 15 Amps 15 Amps
TCIM/TI-430 15 Amps 15 Amps 15 Amps
TCIM/TI-522 15 Amps 15 Amps 15 Amps
TCIM/TI-530 15 Amps 15 Amps 15 Amps
TCIM/TI-622 15 Amps 20 Amps 20 Amps
TCIM/TI-630 15 Amps 20 Amps 20 Amps
Min./Max. voltage supply
Nominal Voltage Minimum No Load Maximum No Load
115 Vo lt s 104 Volts 127 Volts
230 Volts 208 Volts 254 Volts