TRUE ICE SERVICE MANUAL
TEC_TM_198 | REV. A | EN 03/26/2024 Page 87 of 96
truemfg.com
Air-Cooled Ice Machine Specifications & Performance Data (cont.)
TCIM-422-HA1-A/TI-422-MA-S1-A
AC Supply Voltage (V/Hz/Ph) 115/60/1
Amperage [5 min Freeze AT 104˚F (40˚C) / WT 80˚F (27˚C) 6.9
Minimum Circuit Ampacity 15
Maximum Fuse Size 15
Electrical Consumption (kWh/100lb) [AT 90˚F (32˚C) / WT 70˚F (21˚C) 3.8
Water Consumption (gal/100lb) [All Ambients] 14
Batch Size [lb(kg)] 4-4.4 (1.8-2)
Refrigerant [oz(g)] 5.25 (148.8)
Performance Data Sheet
Air Temp
(F˚/C˚)
Water Temp (˚F/C˚)
50/10 70/21 90/32
Ice Production in 24 hours
lb/day - kg/day
70/21
80/27
90/32
100/38
443
428
413
398
202
195
188
181
419
407
396
376
190
185
180
171
395
381
367
354
179
173
167
161
Electric Consumption
Watts
70/21
80/27
90/32
100/38
603
620
632
654
635
654
673
688
667
685
699
723
Freeze Time
mm:ss
70/21
80/27
90/32
100/38
12:33
12:45
13:28
14:28
12:58
13:24
13:49
14:57
13:23
13:36
14:21
15:26
Harvest Time
mm:ss
70/21
80/27
90/32
100/38
01:09
01:04
00:59
00:55
00:57
00:50
00:44
00:45
00:44
00:41
00:38
00:35
Head Pressure
PSIG - kPa
70/21
80/27
90/32
100/38
194
204
215
225
1338
1408
1479
1549
201
206
211
233
1387
1421
1456
1605
208
219
230
241
1435
1510
1587
1662
Suction Pressure
PSIG - kPa
70/21
80/27
90/32
100/38
40
41
41
42
277
281
285
289
45
45
45
46
310
310
310
317
48
49
49
50
331
336
340
345
Total Heat of Rejection from Condenser 5735 BTU/hr [AT 90˚F (32˚C) / WT 70˚F (21˚C)]