Air-Cooled Ice Machine Specifications & Performance Data (cont.)
TCIM-622-HA1-A/TI-622-MA-S1-A
AC Supply Voltage (V/Hz/Ph) 115/60/1
Amperage [5 min Freeze AT 104˚F (40˚C) / WT 80˚F (27˚C) 10.1
Minimum Circuit Ampacity 15
Maximum Fuse Size 20
Electrical Consumption (kWh/100lb) [AT 90˚F (32˚C) / WT 70˚F (21˚C) 4
Water Consumption (gal/100lb) [All Ambients] 14
Batch Size [lb(kg)] 5-5.4 (2.2-2.4)
Refrigerant [oz(g)] 4.9 (138.9)
Performance Data Sheet
Air Temp
(F˚/C˚)
Water Temp (˚F/C˚)
50/10 70/21 90/32
Ice Production in 24 hours
lb/day - kg/day
70/21
80/27
90/32
100/38
628
602
576
550
285
274
262
250
519
574
557
517
268
261
253
235
553
531
507
485
252
241
231
220
Electric Consumption
Watts
70/21
80/27
90/32
100/38
913
955
993
1040
942
977
1013
1073
970
1015
1056
110 6
Freeze Time
mm:ss
70/21
80/27
90/32
100/38
10:25
11:11
11:59
12:45
11: 00
11:29
11:59
13:27
11:34
12:25
13:18
14:09
Harvest Time
mm:ss
70/21
80/27
90/32
100/38
01:08
01:02
00:56
00:50
00:58
00:50
00:43
00:43
00:48
00:44
00:40
00:36
Head Pressure
PSIG - kPa
70/21
80/27
90/32
100/38
204
219
235
250
1409
1513
1620
1724
210
220
231
257
1449
1519
1590
1773
216
232
248
264
1488
1598
1711
1821
Suction Pressure
PSIG - kPa
70/21
80/27
90/32
100/38
39
40
41
42
272
277
283
288
43
43
43
45
297
297
297
308
45
46
47
48
312
317
323
329
Total Heat of Rejection from Condenser 8000 BTU/hr [AT 90˚F (32˚C) / WT 70˚F (21˚C)]