TRUE ICE SERVICE MANUAL
TEC_TM_198 | REV. A | EN 03/26/2024 Page 29 of 96
truemfg.com
Component Identification (cont.)
Temperature Probe Locations (cont.)
Refrigeration System
Left Side View
Rear View
Top View
T-3 Temperature Probe
Located in the Distributer Water Supply Line.
Used to measure Sump Tank water temps.
T-4 Temperature Probe
Located on the Water Inlet Line.
Used to measure incoming water temps.
Micro Channel Condenser
Low Side Process Tube
Evaporator Plate
Start Components
Harvest Valve
TXV
Compressor