TRUE ICE SERVICE MANUAL truemfg.com
TEC_TM_198 | REV. A | EN
P#857284
03/26/2024 Page 88 of 96
Air-Cooled Ice Machine Specifications & Performance Data
TCIM-430-HA1-A/TI-430-MA-S1-A
AC Supply Voltage (V/Hz/Ph) 115/60/1
Amperage [5 min Freeze AT 104˚F (40˚C) / WT 80˚F (27˚C) 6.8
Minimum Circuit Ampacity 15
Maximum Fuse Size 15
Electrical Consumption (kWh/100lb) [AT 90˚F (32˚C) / WT 70˚F (21˚C) 3.75
Water Consumption (gal/100lb) [All Ambients] 14
Batch Size [lb(kg)] 4-4.4 (1.8-2)
Refrigerant [oz(g)] 5.25 (148.8)
Performance Data Sheet
Air Temp
(F˚/C˚)
Water Temp (˚F/C˚)
50/10 70/21 90/32
Ice Production in 24 hours
lb/day - kg/day
70/21
80/27
90/32
100/38
443
430
417
404
201
195
189
184
411
397
383
375
187
181
174
171
395
381
367
354
179
173
167
161
Electric Consumption
Watts
70/21
80/27
90/32
100/38
581
603
621
648
605
626
646
674
628
652
671
700
Freeze Time
mm:ss
70/21
80/27
90/32
100/38
11:47
12:18
12:50
13:21
12:26
13:57
13:28
14:06
13:06
13:41
14:16
14:51
Harvest Time
mm:ss
70/21
80/27
90/32
100/38
01:10
01:03
00:55
00:47
01:07
01:00
00:54
00:45
01:04
00:57
00:50
00:43
Head Pressure
PSIG - kPa
70/21
80/27
90/32
100/38
180
194
208
222
1241
1336
1434
1529
186
198
209
229
1284
1362
1441
1582
192
207
222
237
1327
1428
1533
1635
Suction Pressure
PSIG - kPa
70/21
80/27
90/32
100/38
41
42
42
43
283
287
291
294
46
46
46
47
319
319
319
325
50
50
51
52
342
347
351
356
Total Heat of Rejection from Condenser 5891 BTU/hr [AT 90˚F (32˚C) / WT 70˚F (21˚C)]