TRUE ICE SERVICE MANUAL truemfg.com
TEC_TM_198 | REV. A | EN
P#857284
03/26/2024 Page 92 of 96
Air-Cooled Ice Machine Specifications & Performance Data
TCIM-630-HA1-A/TI-630-MA-S1-A
AC Supply Voltage (V/Hz/Ph) 115/60/1
Amperage [5 min Freeze AT 104˚F (40˚C) / WT 80˚F (27˚C) 9.7
Minimum Circuit Ampacity 15
Maximum Fuse Size 20
Electrical Consumption (kWh/100lb) [AT 90˚F (32˚C) / WT 70˚F (21˚C) 3.8
Water Consumption (gal/100lb) [All Ambients] 14
Batch Size [lb(kg)] 5-5.4 (2.2-2.4)
Refrigerant [oz(g)] 5.1 (144.6)
Performance Data Sheet
Air Temp
(F˚/C˚)
Water Temp (˚F/C˚)
50/10 70/21 90/32
Ice Production in 24 hours
lb/day - kg/day
70/21
80/27
90/32
100/38
622
603
583
564
283
274
265
257
583
576
568
529
265
262
258
241
545
528
511
494
248
240
232
225
Electric Consumption
Watts
70/21
80/27
90/32
100/38
916
952
984
1025
937
963
990
1049
958
996
1029
1072
Freeze Time
mm:ss
70/21
80/27
90/32
100/38
10:33
11: 01
11:29
11:57
11: 08
11:22
11:35
12:37
11:4 4
12:15
12:46
13:17
Harvest Time
mm:ss
70/21
80/27
90/32
100/38
01:18
01:10
01:02
00:54
01:10
00:59
00:48
00:48
01:01
00:54
00:48
00:42
Head Pressure
PSIG - kPa
70/21
80/27
90/32
100/38
198
213
222
243
1368
1469
1572
1673
203
214
225
248
1399
1475
1551
1710
207
222
238
253
1429
1534
1642
1747
Suction Pressure
PSIG - kPa
70/21
80/27
90/32
100/38
39
40
41
42
269
276
283
290
42
42
42
44
286
286
286
306
43
44
46
47
299
306
314
322
Total Heat of Rejection from Condenser 8149 BTU/hr [AT 90˚F (32˚C) / WT 70˚F (21˚C)]