TRUE ICE SERVICE MANUAL
TEC_TM_198 | REV. A | EN 03/26/2024 Page 65 of 96
truemfg.com
Troubleshooting & Diagnosis (cont.)
Problem Causes Possible Solutions
Long Freeze (cont.)
Refrigeration system related (cont.)
Flooding/starving TXV Check TXV bulb clamp/replace TXV
Leaking harvest valve Replace harvest valve
Compressor (weak valves) Replace compressor
Restriction Replace restricted item
Long Harvest
Lack of maintenance
Dirty evaporator/nickel plating
Descale and sanitize per instructions (pg. 51); if nickel
plating is missing, replace the evaporator
Faulty evaporator (missing partitions) Replace evaporator
Excessive scale deposits Descale and sanitize per instructions (pg. 51)
Silicone surrounding evaporator plate not
sealing (should be sealed all the way around
the evaporator)
Reapply silicone
NOTICE
Surface must be dry and clean. Fill any
voids surrounding the evaporator with 100% silicone.
Silicone should be cured before starting the unit.
Improper Installation
Not level Level the unit by adjusting bin/dispenser legs
Low ambient temperature
(below 35˚F (1.7˚C))
Move the unit or increase the ambient temperature
Electrical system related
Faulty harvest valve (not opening all
the way)
Verify HGV coil voltage is correct
Open harvest valve coil Replace HGV coil
Harvest valve relay (on control board)
not closing
Replace control board
Proximity switch (bin switch) stuck closed Replace proximity switch (bin switch)
Condenser fan(s) should not run
during defrost)
Check wiring. If wired incorrectly, correct wiring per
wiring diagram; If control board sends voltage to
condenser fans during harvest, replace the control
board
Refrigeration system related
NOTICE
If the compressor discharge line temperature (measured 6" (153 mm) from the
compressor) falls below 140˚F (60˚C) when harvest initiates, the unit will not have the designed
temperature required for harvest
Low Charge Check refrigeration system for leaks
Incorrect charge
Vacuum refrigeration system and weigh in the
correct charge
Incorrect refrigerant Verify only R-290 refrigerant is being used
Non-condensables in the system Replace the drier and pull 500 mic vacuum
Flooding/starving TXV Check TXV bulb clamp/replace TXV