Grounding Instructions
This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of elec-
tric shock by providing an escape wire for the electric current. This oven is equipped with a cord that has a
grounding wire with a grounding plug, which must be plugged into an outlet that is properly installed and
grounded. Consult a qualified electrician or serviceman if uncertain about the ability to follow grounding
instructions or if doubt exists as to whether the appliance is properly grounded.
X
DO NOT use an extension cord. If the power cord is too short, have a qualified electrician or
serviceman install an outlet near the appliance.
WARNING: Improper grounding can result in risk of electric shock.
Power Cord Replacement
If the power cord is damaged, it must only be replaced by the manufacturer, its service agent, or a
similarly-qualified person.
Precautions to be Observed Before and During Servicing to Avoid Possible
Exposure to Excessive Microwave Energy
(a) DO NOT
operate or allow the oven to be operated with the door open.
(b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other
microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing,
(3) seal and sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges
and latches, (5) evidence of dropping or abuse.
(c) Before turning on microwave power for any service test or inspection within the microwave
generating compartments, check the magnetron, wave guide or transmission line, and cavity for
proper alignment, integrity, and connections.
(d) Any defective or misadjusted components in the interlock, monitor, door seal, and microwave
generation and transmission systems shall be repaired, replaced, or adjusted by procedures described
in this manual before the oven is released to the owner.
(e) A microwave leakage check to verify compliance with the Federal Performance Standard should be
performed on each oven prior to release to the owner.
Refer to pages 25-26 for leakage test procedures.
RF Interference Considerations
The i3 oven generates radio frequency signals. This device has been tested and was determined to be in
compliance with applicable portions of FCC part 18 requirements and to the protection requirements of
Council Directive 89/336/EEC on the approximation of the laws of the Member States relating to
electromagnetic compatibility at the time of manufacture. However, some equipment with sensitivity to
signals below these limits may experience interference.
If your equipment experiences interference:
Increase the physical separation between this oven and the sensitive equipment.
If the sensitive device can be grounded, do so following accepted grounding practices.
If battery-powered microphones are being affected, ensure that the batteries are fully charged.
Keep sensitive equipment on separate electrical circuits if possible.
Route intercom wires, microphone wires, speaker cables, etc. away from the oven.
ii SAFETY INSTRUCTIONS

Table of Contents

Other manuals for TurboChef i3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the TurboChef i3 and is the answer not in the manual?

TurboChef i3 Specifications

General IconGeneral
Modeli3
Cooking ChamberStainless Steel
Cavity Dimensions14.5 x 16 x 10 inches
Power Requirements208-240V, 30A