INFO, TEST, AND EDIT MODE TOUCH
29
Service Screen
From the Service screen, view:
- Fault Log
- Counters and Timers
- Test Mode
Fault Log:
View the faults by Count or History. Use the toggle
to change between count view and history view.
Faults by Count:
Shows the number of faults occurred by fault code.
Press “Reset” to reset all counters to 0 and press the
down arrow to view the rest of the fault codes.
Faults by History:
View time stamps of each fault occurrence and the
fault code.
Counters and Timers:
From the Counters screen, view:
- Cook counter
- Total cook time
- Magnetron time
- Total time (oven on)
- Power cycles: The number of times the oven
has cycled power.
Test Mode:
Test Mode allows the service technician to test
individual components to verify operation.
From Test Mode, perform the following:
- View Status Indicators
- Magnetron Test
- Heater Control
- Control Top/Bottom Blower Speed
- Stirrer Control
View Status Indicators:
- P = Primary switch (backlit = open)
- S = Secondary switch (backlit = open)
- M = Monitor switch (backlit = open)
- t = Magnetron thermostat (backlit = open)
- H = Heater (backlit = off)
- B = Bottom Blower Motor (backlit = off)
- T = Top Blower Motor (backlit = off)
- W = Microwave (backlit = off)