Diagnostic Tests
iSTAR Ultra Installation and Configuration Guide 10–7
To Activate Input Change Display Tests
Set the SW3 rotary switch to the positions shown in Table 10-6.
Ethernet Port Test
The onboard Ethernet tests display diagnostic information about Ethernet connections.
To Test the Ethernet Port
1. Set switch SW3 to the position shown in Table 10-7 on page 10-7.
2. Observe the LCD display for test results.
Table 10-6: Input Test Switch Settings
Switch Position Function
SW3 set to 3 Two-second LED input change display is on (slow mode)
SW3 set to 4 One-second LED input change display is on (fast mode)
Table 10-7: Ethernet Test Switch Settings
Switch Position Function
SW3 set to 8 Tests the Ethernet Port