Doc No. FM0804 issue 4 Page 17
11. NETWORK CABLE COLOUR CODE
6 PAIR CW1308 SYSTEM NETWORK CABLE
Pair No.
Diameter
Colour
Terminal
Signal
1
2 x 0.5 mm
White/Blue
24V
Power
Blue/White
2
2 x 0.5 mm
White/Orange
0V
Orange/White
3
0.5 mm
White/Green
TX+
RS485
Green/White
TX-
4
0.5 mm
White/Brown
SP1
Audio 1
Brown/White
SP2
5
0.5 mm
White/Grey
MIC1
Grey/White
MIC2
Audio 2
6
0.5 mm
Red/Blue
SP1
Blue/Red
SP2
10 PAIR CW1308 DOOR PANEL NETWORK CABLE
Pair No.
Diameter
Colour
Terminal
Signal
1
2 x 0.5 mm
White/Blue
24V
Power
Blue/White
2
2 x 0.5 mm
White/Orange
0V
Orange/White
3
0.5 mm
White/Green
TX+
RS485
Green/White
TX-
4
0.5 mm
White/Brown
SP1
Audio 1 Door
Panel Spk & Mic
Brown/White
MIC1
5
0.5 mm
White/Grey
SP1
Audio 2 Door
Panel Spk & Mic
Grey/White
MIC2
6
0.5 mm
Red/Blue
C1
Audio 1 Tel
Spk & Mic
Blue/Red
C2
7
0.5 mm
Red/Orange
C1
Audio 2 Tel
Spk & Mic
Orange/Red
C2
TUNSTALL SYSTEM NETWORK CABLE
If using an existing 5 pair Tunstall Telecom cable always ensure none of the original equipment is left connected
before terminating the Advent XT2 system. Use the following colour code;
Pair No.
Diameter
Colour
Terminal
Signal
1
0.8 mm
Red
24V
Power
Black
0V
2
0.5 mm
White
TX+
RS485
Blue
TX-
3
0.5 mm
Grey
SP1
Audio 1
Yellow
SP2
4
0.5 mm
Orange
MIC1
Brown
MIC2
Audio 2
5
0.5 mm
Violet
SP1
Turquoise
SP2
Other cable networks from previous systems can be used provided there are a minimum of 5 x 0.5mm twisted pairs maintained throughout the site.
Check the overall cable resistance from one end to another, check there is no resistance between cores and check the cables are voltage free.
NETWORK CABLE LIMITATIONS
The maximum network cable length is 1200 metres - beyond this it is likely you will experience problems relating to
voltage-drop, low audio levels and corrupt data. Voltage-drop can be overcome by increasing cable conductor size and
adding additional PSU’s. Low audio levels can only be overcome by increasing cable conductor size. Corrupt data can
be caused by cable length and/or too many devices on the network, a Network Data Repeater (P/No. ZXT340) is
available for extreme cases.