YK11-0016-DI-002-08
xv
0.5.2 Transfer
WARNING
You have a risk of giving damage to
your back as the load larger than
safety standard shall be required to transfer the product.
PMB100D : 26kg
PMB300D : 51kg
PMB600D : 82kg
PMB1200D : 115kg
PMB2400D : 260kg
Be sure to use the loading machinery (such as mobile crane) to
lift up
the Pump or load it on the pallet and fix it and run the Pallet truck for
its transfer.
Never try to enter beneath the Pump unit when lifted it up.
Use sling belts to load/unload the unit.
Do not put the folk of the Fork lift or the like in
the Pump bottom
(exhaust outlet) to lift it.
Note to purge the oil to transfer the pump. If forced to transfer
remaining the oil, be sure to keep the pump horizontal.
Do not tilt the pump 10 degree or more while you charge the oil.
The oil might run into the casing.