YK11-0016-DI-002-08
1
1. For Your Safety Use
1.1 This Product Intrinsic Hazardous Nature and Safety Measures
Before operating or checking this machine, thoroughly read this paragraph, and after fully
understanding about latent danger and on how to avoid danger, perform the work.
1.1.1 ! Danger Leakage of dangerous gas and dangerous materials
Factors Avoidance methods and measures
Leakage
of poisonous and combustible
gas
Getting injured on touching any toxic
pump oil, pump, generated material or
sucked substance at the occasion of
Do not exhaust any hazardous gas
such as toxic and combustible.
When you check the
wear a brace that supports the toxic
substances that exhaust the pump.
To overhaul or dispose,
ask the special agency to do the
detoxification process.
Ask the disposal agency licensed by
the administration for disposal.
1.1.2 ! Warning Transfer of heavy material
Factors Avoidance methods and measures
Getting injured on
transferring
the pump Pump weight
PMB100D : 26kg
PMB300D : 51kg
PMB600D : 82kg
PMB1200D : 115kg
PMB2400D : 260kg
Only technically entitled person
loading/unloading and operating
There is a risk that the Pump might
drop or lay down when attempted
unreasonable
setup was not sufficient.
You are strictly restricted from entering
beneath the Pump.
1.1.3 ! Warning Electric shock
Factors Avoidance methods and measures
Getting electrical shock
on touching the
current-carrying part of
the motor.
Be sure to cut the electricity to do
Ensure to close the cover of motor
terminal box and never open it during
Be sure to cut the electricity to do
Never attempt to put in the hand or bar
into the opening of the Motor.
Motor terminal mount
gets burnt.
Tighten close the terminal.
Check the tightening once a month.
(Refer to “3.5 Electrical Connection”)