1.1.4 ! Warning Explosion
Factors Avoidance methods and measures
Pressure inside the pump rises up and
the pump explodes.
Ensured pressure value of the Pump is
0.03MPaG
2
Check the Exh
aust side pressure of the
pump.
If it was over 0.03 MPaG (0.3 kg/cm
2
G)
(Gauge pressure) take away anything
in and around the exhaust outlet that
1.1.5 ! Caution High temperature
Avoidance methods and measures
Getting burnt on touching the high
temperature part.
The Pump gets high temperature
As the surface temperature is high, you
have a risk of getting burnt by
accidentally touching it with the hand
or the like. Refrain from touching the
pump during operation. Wait until the
temperature sufficiently cools down
after having stopped the pump to
conduct check or something.
1.1.6 ! Caution Leakage of hot cooling water
Avoidance methods and measures
Kept operating without supplying the
cooling water
. Boiled hot vapor jet out
the cooling water outlet.
Put a Flow meter in the line to set the
interlock so that the Pump stops when
If you kept operating without
the water, immediately stop the Pump
Stop the Pump and ensure that the
Pump temperature got cooled down to
take out the Pump and check it.