EasyManua.ls Logo

Ulvac PMB100D - Page 32

Ulvac PMB100D
119 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
YK11-0016-DI-002-08
5
Table. 2 Details Model list
Specification
Material Feature Primary use
PMB_D
Standard
Aluminum
Adsorption to the surface is
small, low-emission gas
Clean Air ꞏ inert gas exhaust.
Fore, such as pump exhaust
chamber / load lock of TMP.
PMB_D-T
Surface treatment
Aluminum Alumite
treatment
Improved corrosion resistance.
Hard surface
Exhaust gases and corrosive
solvents
●PMB100D(IE2 motor) 1
Motor Destination Corresponding voltage Inverter
Totally-enclosed
fan-cooled
200V class motor
Japan
200V50Hz
200/220V60Hz
200240V50/60Hz
Totally-enclosed
fan-cooled
Multi rated Motor
Overseas
220240V50Hz
208240V60Hz
380415V50Hz
380460V60Hz
200240V50/60Hz
380480V50/60Hz
●PMB300,600,1200,2400D(IE3 motor) 2
Motor Destination Corresponding voltage Inverter
Totally-enclosed
fan-cooled
Multi rated Motor
Overseas
200240V50Hz
200240V60Hz
380415V50Hz
380460V60Hz
200240V50/60Hz
380480V50/60Hz
1) Motor for PMB100D is IE3 unregulated.
2)
200V in the multi-voltage counterparts motor (50Hz), 200V (60Hz), it can respond to 220V (60Hz).
There is not any naming for standard spec. Spec. H, F, T, TH or TF is selectable as option.
Options for pump head and accessories are different depending on the type.
You can not select the combination + increased safety explosion-proof inverter, the inverter +
flameproof.

Table of Contents