Table. 4 Motor : class 200V for Japan ※15
kW (poles)
the connection inside
the terminal box
RATED CURRENT A
RATED VOLTAGE V
Model
Motor
1.79A (200V-50Hz)
1.68A (200V-60Hz)
1.60A (220V-60Hz)
0.4 (2)
PMB100D
Totally-Enclosed Fan-Cooled Flange Induction Motor
delta(△)
Table. 5 Motor : Multi rated ※15, 16
kW (poles)
delta(△) star(Y) delta(△) star(Y) delta(△) star(Y)
1.65A (220V-50Hz)
1.69A (240V-50Hz)
1.61A (208V-60Hz)
1.52A (220V-60Hz)
1.47A (240V-60Hz)
0.96A (380V-50Hz)
0.98A (415V-50Hz)
0.88A (380V-60Hz)
0.85A (460V-60Hz)
3.10A (200V-50Hz)
3.00A (220V-50Hz)
3.10A (240V-50Hz)
3.10A (200V-60Hz)
3.00A (208V-60Hz)
2.80A (220V-60Hz)
2.70A (240V-60Hz)
1.70A (380V-50Hz)
1.80A (415V-50Hz)
1.60A (380V-60Hz)
1.60A (460V-60Hz)
8.30A (200V-50Hz)
8.20A (220V-50Hz)
8.20A (240V-50Hz)
8.00A (200V-60Hz)
7.70A (208V-60Hz)
7.30A (220V-60Hz)
7.00A (240V-60Hz)
4.70A (380V-50Hz)
5.20A (415V-50Hz)
4.20A (380V-60Hz)
4.20A (460V-60Hz)
PMB100D PMB300DModel PMB600D
2.2 (2)0.4 (2)
Motor Totally-Enclosed Fan-Cooled Flange Induction Motor
0.75 (2)
RATED CURRENT
A
RATED VOLTAGE
V
the connection inside
the terminal box ※15
kW (poles)
delta(Δ) star(Y) delta(Δ) star(Y)
12.7A (200V-50Hz)
12.0A (220V-50Hz)
12.4A (240V-50Hz)
12.6A (200V-60Hz)
12.2A (208V-60Hz)
11.6A (220V-60Hz)
10.7A (240V-60Hz)
6.90A (380V-50Hz)
7.10A (415V-50Hz)
6.60A (380V-60Hz)
6.00A (460V-60Hz)
25.7A (200V-50Hz)
23.9A (220V-50Hz)
23.8A (240V-50Hz)
25.7A (200V-60Hz)
24.4A (208V-60Hz)
23.0A (220V-60Hz)
21.7A (240V-60Hz)
13.8A (380V-50Hz)
13.8A (415V-50Hz)
13.5A (380V-60Hz)
11.9A (460V-60Hz)
Motor Totally-Enclosed Fan-Cooled Flange Induction Motor
PMB1200D
3.7 (2)
RATED CURRENT
A
RATED VOLTAGE
V
the connection inside
the terminal box ※15
7.5 (2)
Model PMB2400D
※15) The pump has either the motor class 200V for Japan OR the motor multi rated.
PMB300,600,1200,2400D is capable of corresponding 200V (50Hz), 200V
(60Hz), 220V also (60Hz) in multi-rated counterparts motor.
※16) Multi rated Motor
By connection change in motor terminal box, this pump works at the
prescribed voltage without exchange motor.
Before wiring, please check the power supply voltage to be used. Check the
power supply voltage to be used, please do the switching of the terminal box