2. Operation Manual Page 6
Pre-Operation Safety Inspection
P
RE
-O
PERATION
S
AFETY
I
NSPECTION
NOTE: Carefully read, understand and follow all safety rules, operating instructions, labels and National Safety
Instructions/Requirements. Perform the following steps each day before use.
1. Open modules and inspect for damage, fluid leaks or missing parts.
Figure 3: Hydraulic Tank
2. Check the level of the hydraulic fluid
with the platform fully lowered. The
hydraulic reservoir is located at the
rear of the machine. The fluid level
should be visible through the side of
the tank, and must be between the
MIN and MAX lines (see Figure 3).
Add hydraulic fluid if necessary.
3. Check that fluid level in the batteries
is correct (See Battery Maintenance,
page 9).
4. Verify that batteries are charged.
5. Check that A.C. extension cord has
been disconnected from the plug in
the left Chassis
Module, and that the module doors
are closed and locked.
6. Check that all guardrails are in place and all fasteners are properly tightened.
7. Inspect the machine thoroughly for cracked welds and structural damage, loose or missing hardware,
hydraulic leaks, damaged control cable, loose wire connections and wheel bolts.
Hydraulic Fluid
Tank

Table of Contents

Other manuals for Upright NX15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Upright NX15 and is the answer not in the manual?

Upright NX15 Specifications

General IconGeneral
BrandUpright
ModelNX15
CategoryLifting Systems
LanguageEnglish

Related product manuals