Troubleshooting 4.5 - Fault Codes
503727-002
4.5 FAULT CODES
01 – System initialization error
02 – System communication error
22 – Platform Left Turn Switch ON at power-up
23 – Platform Right Turn Switch ON at power-up
25 – Platform Hi-Drive Switch ON at power-up
27 – Platform Lo-Drive Switch ON at power-up
28 – Platform Lift Switch ON at power-up
29 – Platform Joystick Enable Switch ON at power-up
31 – Platform Joystick not in neutral at power-up
32 – Lower Control Up/DownToggle ON at power-up
39 – Lower Control Enable Switch ON at power-up
54 – Pothole Retract Coil fault
55 – Lift Up Coil fault
56 – Lift Down Coil fault
59 – Steer Right Coil fault
61 – Steer Left Coil fault
66 – Forward Coil fault
67 – Reverse Coil fault
68 – Low Battery fault