Vaisala DMP248 - Selecting the analogue outputs

Vaisala DMP248
141 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATING MANUAL_______________________________________________________________
22_____________________________________________________________________M210492EN-A
Connections
V
mA
+
-
CH1+
CH1 -
CH2
+
CH2 -
24 V +
X2
X1
V
mA
+
-
CH1- and CH2- are connected
together internally
CURRENT/VOLTAGE
OUTPUTS
POWER SUPPLY
(INTERNAL OR
EXTERNAL)
Do not use power supply
ground (-) as output signal
ground
OPENED COVER OF THE DMP248
FIGURE 3-17 Electrical connections
Power supply 24 VDC
24 VAC (see Chapter Connection
to an AC supply)
Output signals 0...20 mA
4...20 mA
0...1 V
0...5 V
0...10 V
Power supply ground (-) is connected to the housing with parallel
connection of 15 nF capacitor and 300 k resistor.