Compact Keypad User Manual
To delay setting by the configured time (default 30 minutes):
Press the soft key below the Delay Timer symbol.
Example:
TIME TO FULLSET
68 MIN 30 SEC.
You can press this soft key up to 3 times by default (configurable by
installer) to increment the configured time. In this case, the icon is no
longer displayed.
To cancel automatic setting for a standard area:
Press the soft key below the Cancel Timer symbol.
The Timer Info and Delay Timer icons are no longer displayed. You must
manually set this area.
7.6 Time Locked
Time locked applies to a vault type of area only. If time locked is applied to a vault
area, you can only unset the vault during times defined by the assigned calendar.
The padlock symbol is displayed next to the vault area to indicate when it cannot
be unset.
The Time Lock symbol indicates if a vault
area is time locked. This means that the
vault area cannot be unset outside of the
times defined by the calendar assigned to
the area.
7.7 Interlocked Areas
Vault and ATM area types can be interlocked. This means that if more than one of
these area types is assigned to the same Interlock group, only one of the group
may be unset at a time. A padlock symbol displays next to an interlocked vault or
ATM area to indicate that it cannot be unset. Once you set one area in the group,
the padlock symbol is removed to indicate that you can unset another area in the
interlock group. When a calendar is assigned to an interlocked group to unset
automatically, the first area listed in the interlocked group will unset first and the
Timer Info and Timer Delay symbols will display as described in the section
Automatic Calendar Setting [➙ 25]. It is not possible to cancel setting for an ATM
or Vault area.