© by N&W GLOBAL VENDING S.p.A. 34 02-2014 4535 00
taNk
The machine can be supplied by mains or internal tank.
With this function you can dene whether the device is
powered from the mains (tank = OFF), from tank with
water level sensor (tank = ON).
first coffEE HEatiNg timE
It allows the user to enable and set the heating time (in
seconds) of the rst coee after a period of standby
soliD rEsiDuE maNagEmENt
This function allows you to enable and set the number of
selections of espresso after which the machine displays
the request to empty the solid residue container.
ENErgy saviNg:
With this option it is possible, in the time intervals which
are set with the function “Energy Saving Parameters”, to
suspend the service of the vending machine and switch
o or not the boiler
- Off: energy saving management disabled
- On: energy saving management enabled, it is possible
to decide whether or not to shut down the boilers
ENErgy saviNg paramEtErs
With this function it is possible to set up to 2 time bands
during which the energy saving proles will switch on.
To disable the time band, set the start and end times to
00.00.
lED
It is possible to dene whether the lighting LEDs shall
be switched on or not when the machine is operating or
“Out of service”.
macHiNE sErial NumbEr
With this function it is possible to vary the eight-digit
numerical code which identies the machine (00000000
as default)
faN maNagEmENt
This function allows you to enable the continuous opera-
tion of the steam extractor fans during preparation of the
drinks which use instant powders.
- ON extractor fans in continuous operation
- OFF extractor fan in operation only during the prepara-
tion of the drink and for the 30 subsequent seconds.
powEr supply
It allows the user to set the type of electrical connection
used to power the device.

choice.
You can choose from:
- 16A single phase
- three-phase
- 38A single phase
iNitializatioN
This function shall be used in case of error of the data in
the memory or if the software is replaced.
All the statistical data, with the exception of the general
electronic counter, will be reset.
The initialization resets all default data on the machine.
The following parameters are requested:
macHiNE coDE
Insert the machine code of the device, the machine code
is detectable by the data plate located inside the appli-
ance door. (see “machine identication and characteris-
tics” on page 2)
NatioN
understood as a type of basic doses for the various
selections
(e.g. IT coee = 60 cc - FR coee = 106 cc).
The “nations” provided vary, depending on the model.
lay out
for each model and type of doses, there are a number of
button-Selection Un Certain combinations among Which
it is possible to choose (the For Each layout combina-
tions at the doses are indicator-table selections Supplied
with the machine).