© by N&W GLOBAL VENDING S.p.A. 33 02-2014 4535 00
Only for models with a cappuccino maker, it allows you
to establish some features of cappuccino maker.
Allows you to set the density of the milk foam (size of the
bubbles).
Low values ensure a smaller bubble.
The value “0” means no bubbles
It sets the emptying time needed for the milk to ow back
into the container, as well as the milk circuit lling time,
when the fresh milk container is not positioned on the
same level as the device.
After making changes to the milk circuit lling/emptying
times, it is necessary to change the cappuccino maker
“air time” and “steam time” in order to get a proper prepa-
ration of the frothed milk
It sets the time of execution of the cappuccino maker
cleaning cycle.
It allows the user to:
- enable/disable the cappuccino maker rinse after a
selection with fresh milk
- the number of minutes after which to rinse the cappuc-
cino maker with fresh milk following the last selection
- enable/disable the periodic rinse of the cappuccino
maker
- Sets the amount of water (CDV) to be used during the
rinse.
This function allows you to determine the pre-infusion
parameters:
- the quantity of water (in cdv)
- the pre-infusion time (in tenths of a second) before the
infusion occurs.
It allows the user to choose the selection of reference
for every grinder in the machine that has the automatic
grinding adjustment the enabled.
DISPLAY
It is possible to choose the language, among those fore-
seen by the software, used for the messages shown on
the touchscreen.
Display NumbEr of strokEs at start-up
Enables the display of the total number of items dis-
pensed since the last reset, during the machine start-up
phase.
It allows the user to set after how long (in minutes) the
screen saver is activated.
A value of 0 indicates that the screen saver is disabled.
MACHINE SETUP
Date and time are displayed (if enabled), but also used
to manage the time frame and statistics.
In the absence of power supply the machine maintains
the set date and time by means of a buer battery.
This function allows you to set the current date.
This function allows you to set the current time.
This function allows you to set the working temperature
(in °C) of the boiler.
Use “+” and “-” to change the default settings.
It is a 5 digit code, needed to access the programming
menus.
By default, the value of this code is set to 00000
From this group of functions the password for the vari-
ous menus (Technical, Manager, USB, washes) can be
enabled and set.
Only for models with cooling unit with empty milk sensor.
- OFF: sensor disabled
- ON: in the absence of milk, the selections that use it
are disabled, in normal operation the message “Fresh
milk finished” is shown