To configure general network settings:
1. Click the Network tab, then click the General tab to display the switch General Network
Settings screen.
2. Select one of the following options from the LAN Speed drop-down menu: Auto-Detect, 10
Mbps Half Duplex, 10 Mbps Full Duplex, 100 Mbps Half Duplex or 100 Mbps Full Duplex.
NOTE: You must reboot if you change the Ethernet mode.
3. Select either Enabled or Disabled in the ICMP Ping Reply drop-down menu.
4. Verify or modify the HTTP or HTTPS ports. The settings will default to HTTP 80 and HTTPS
443.
5. Click Save.
To configure IPv4 network settings:
1. Click the Network tab, then click the Address tab to display the IPv4 Settings screen.
2. Click the IPv4 button.
3. Click to fill or clear the Enable IPv4 checkbox.
4. Enter the desired information in the Address, Subnet and Gateway fields. IPv4 addresses are
entered as the xxx.xxx.xxx.xxx dot notation.
5. Select Enabled or Disabled from the DHCP drop-down menu.
NOTE: If you enable DHCP, any information that you enter in the Address, Subnet and Gateway fields
is ignored.
6. Click Save.
To configure IPv6 network settings:
1. Click the IPv6 button.
2. Enter the desired information in the Address, Subnet and Prefix Length fields. IPv6 addresses
are entered as the FD00:172:12:0:0:0:0:33 or abbreviated FD00:172:12::33 hex notation.
3. Select Enabled or Disabled from the DHCP drop-down menu.
NOTE: If you enable DHCPv6, any information that you enter in the Address, Gateway and Prefix
length fields is ignored.
4. Click Save.
4.8 SNMP Settings
SNMP is a protocol used to communicate management information between network management
applications and the switch. Other SNMP managers can communicate with your switch by accessing MIB-
II. When you open the SNMP screen, the OBWI will retrieve the SNMP parameters from the unit.
From the SNMP screen, you can enter system information and community strings. You can also designate
which stations can manage the switch as well as receive SNMP traps from the switch. If you select Enable
SNMP, the unit will respond to SNMP requests over UDP port 161.
To configure general SNMP settings:
1. Click SNMP to open the SNMP screen.
2. Click to enable the Enable SNMP checkbox to allow the switch to respond to SNMP requests
over UDP port 161.
4 OBWI Operation
35

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vertiv Avocent AutoView 2108 and is the answer not in the manual?

Vertiv Avocent AutoView 2108 Specifications

General IconGeneral
BrandVertiv
ModelAvocent AutoView 2108
CategorySwitch
LanguageEnglish

Related product manuals