8.15 Maintenance table
Several times per day
Task Recommended interval Procedure / Parts Tool illustration
Checking the external compressed
air lines for damage
Before switching on the
machine
Visual check
Checking the suction hose for
damage
Before switching on the
machine
Visual check
Once per day
Task Recommended interval Procedure / Parts Tool illustration
Checking the compressed air regu-
lator
(page 45)
Before work
Clean or exchange cartridge
in case of visible contam-
ination or every 2 years
If necessary, new filter cart-
ridge
Daily cleaning of the working
chamber
(page 42)
After work
If soiled
Vacuum cleaner, Brush, Dry
cloth
Once per week
Task Recommended interval Procedure / Parts Tool illustration
Cleaning the collet chuck
(page 43)
Once per week
In case of rotational imper-
fections
Spindle service set
When necessary
Task Recommended interval Procedure / Parts Spare part illustration
Updating the software and firm-
ware
(page 51)
When an update is available
Additional cleaning of the working
chamber
(page 42)
When the webcam is soiled
When the view window is
soiled
Dry cloth
Cleaning the housing
(page 46)
Microfiber cloth, Water, Mild
cleaning agent (optional)
Exchanging the main fuse
(page 46)
Replacement fuse T6,3A
L250V
Replacing the clamping system of
the blank holder
(page 49)
Clamping system blank holder
K5+ Maintenance and do-it-yourself
EN 52
Original Operating Instructions:K5+
Version: 12/16/2021

Table of Contents