Terminal Signal In/Output Description
X9.23 EMERGENCY RE-
SET IN
Input Connection for the external emer-
gency stop reset button. When the
safe state has been restored the
power supply module of the laser
switchen on by pushing this button.
Connection of the button between
X9.1 and X9.23.
X9.24 EMERGENCY
FEEDBACK OUT
Output Feedback output for forceguided
contacts of the extension relays.
Default: Bridge to X9.22
Wiring see Safety Circuit Variant 2 [} 89].
09/17 - Index: AD [EN]
68
Videojet 3140/3340/3640/8 Appendix