3.5 Cooling
The laser system is cooled by air. The internal cooling system is designed to sup-
ply sufficient cooling.
Make sure that the cooling air can be sucked in and blown out freely and that
there is sufficient air exchange at the installation site to ensure heat dissipation.
3.6 Fume Extractor
In order to remove marking residues which might be dangerous to health a fume
extractor must be installed.
The fume extractor is to be installed such that marking particles are sucked off di-
rectly at the place of the formation to prevent the accumulation of dust particles
which gradually destroy optical components of the laser system. Make sure that
there are no air leaks.
We offer fume extractors as accessories. If a fume extractor is part of the com-
plete delivery please find further information in the enclosed operation manual of
the fume extractor
3.7 Interfaces of the Laser System
Network interface (stand-
ard)
Connection of a PC for controlling via Smart
Graph software (the connecting cable is deliv-
ered).
Optional interfaces:
- Handheld (M16) Connection of the Handheld. Electrical power for
the Handheld is supplied by the switched-on laser
system.
- Touch PC (M16) Connection of the Touch PCs for controlling via
Touch Control Software. Electrical power for the
Touch PC is supplied by the switched-on laser
system.
- CLARiTY (RJ45) Connection of the CLARiTY Laser Controller.
Electrical power for the CLARiTY Laser Controller
must be supplied separately.
09/17 - Index: AD [EN]