18. Coolant system (optional)
18.4 Filling the coolant system
A number of protective measures must be observed and taken in order to ensure that the handling of
coolant does not cause health risks or environmental loads.
Always observe the datasheet and the safety regulations of the coolant being used (can be
obtained from the supplier or manufacturer)
Observe all safety regulations set out in these operating instructions, in particular those that refer
to the safe handling of coolants.
In order to ensure reliable operation of the coolant pump, a minimum coolant filling level is required
in the coolant tank.
The capacity of the coolant system is approximately 19 litres.
The maximum filling level should be just below the shelf insert
The minimum filling level is approximately 15 mm below that.
To fill, remove the shelf insert and fill to the maximum filling level with a suitable coolant whilst
observing all safety regulations.
After filling, replace the shelf insert
18.5 Operating the coolant system
The switch shown below is located on the mains cable of the coolant pump.
Switch position ( 0 ) Pump switched off
Switch position ( I ) Pump switched on
(Caution: Coolant flow is controlled with the coolant shut-off valve)