OM 25-3503 us – Edition 4.1 * 2503_3503b530.fm 5-33
Maintenance
5.15 Maintenance when out of service for a longer period of time
NOTICE
If the machine is out of operation, run it once a month without load. Remove
the grease from the piston rods first!
Preparatory work before taking out of service
☞ Carefully clean and dry the entire machine.
☞ Apply grease to all lubrication points
☞ Change the engine oil
☞ Apply grease to the piston rods of the hydraulic cylinders
☞ Check and if necessary, fill up all oil levels such as in the gearbox and other units
☞ Check the hydraulic oil level and if necessary, add oil
☞ Fill up the fuel tank completely to avoid corrosion on the walls
☞ Check the antifreeze in the coolant, change as required
☞ Check the tire pressure for the prescribed value and protect the tires from direct sunlight
☞ Remove the grounding strap from the battery, or remove the battery and store it in a
safe place. Charge the battery and perform battery maintenance at regular intervals.
☞ Close the exhaust pipe and the air intake opening of the air filter system
Information!
Store the machine indoors if possible. If storing the machine outdoors cannot
be avoided, place it on wooden boards and cover it with a tarp.
Permanently putting out of operation
All fluids, lubricants, material, etc., used on the machine are subject to specific regulations.
Dispose of different materials and consumables separately and in an environmentally
friendly manner.
Have disposal only performed by a Wacker Neuson service center.
Environment!
Avoid damage to the environment. Do not allow environmentally damaging
wastes to get into the ground or stretches of water and dispose of them in an
environmentally friendly manner.
.
If the machine is no longer used according to its designated use, ensure that it is put out of
operation and disposed of according to applicable regulations.
➥ Observe all applicable safety regulations during machine disposal.
➥ Machine disposal must be performed in accordance with state-of-the-art standards that
apply at the time of disposal.