EasyManua.ls Logo

Wacker Neuson 2503 - Operation; Starting with the immobilizer (option)

Wacker Neuson 2503
280 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OM 25-3503 us – Edition 4.1 * 2503_3503b330.fm 3-23
Operation
3.10 Starting with the immobilizer (option)
After you have completed the starting preparations:
☞ Approach the transponder key to about 2 cm from the emitter/receiver unit 27
☞ The machine can be started as soon as the red indicator light 26 goes out
☞ Insert the starting key in the preheating start switch 19 within 30 seconds and
☞ Turn the starting key at least to position “1”
☞ Check whether all indicator lights illuminate:
☞ Replace malfunctioning indicator lights immediately.
☞ Turn the starting key to position “2” and hold it in this position for about 5 seconds
➥ The intake air is preheated
☞ Turn the starting key to position “3” and hold it in this position until the engine starts
➥ If the engine does not start after 10 seconds
☞ Interrupt the start procedure and try again after about 1 minute
➥ If the engine still does not start after the second try
☞ Contact a Wacker Neuson service center for troubleshooting
➥ As soon as the engine runs:
☞ Release the starting key
Fig. 91: Immobilizer
Fig. 91: Preheating start switch
Fig. 91: Indicator lights
1
0
2
3
19
26
27

Table of Contents