EasyManuals Logo

Wacker Neuson 2503 User Manual

Wacker Neuson 2503
280 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #228 background imageLoading...
Page #228 background image
5-46 OM 25-3503 us – Edition 4.1 * * 2503_3503b550.fm
Wartung
Information!
Maintenance with the note Wacker Neuson service center must be per-
formed only by the trained and qualified personnel of a Wacker Neuson ser-
vice center.
Every 1000 operating hours or once a year (Wacker Neuson service center)
Change the hydraulic oil --
Replace the breather filter of the hydraulic oil reservoir --
Replace the gearbox oil in the traveling drive, axles and transfer gearbox --
Replace the air filter element
1
--
Replacing the crankcase breather filter --
Check valve clearance, adjust if necessary
2
--
Check the pressure of the primary pressure limiting valves of the operating hydraulics --
Check the antifreeze --
Check the battery condition (charge condition, terminals, etc.) --
All steps for maintenance once a day and once a week (and all steps for maintenance at 500 operating hours) --
Option
Wear of load hook and joint rod (check at least once a year) --
1. Air filter replacement according to the dirt indicator, every 1000 o/h or once a year at the latest. (Replace after 50 o/h when in extensive use in environments with acidic air, such as acid production
facilities, steel and aluminum mills, chemical plants and other nonferrous-metal plants, independently of the dirt indicator)
2. If equipped with a Perkins engine: have performed by a Perkins service center.
Every 2000 operating hours or every 2 years (Wacker Neuson service center)
Check the bladder type accumulator --
All steps for maintenance once a day and once a week (and all steps for maintenance at 500 and 1000 oper-
ating hours)
--
Every 3000 operating hours or every 3 years (Wacker Neuson service center)
Check the injection nozzles and clean them if necessary --
Clean the particulate matter catalyst, replacement program --
Check the exhaust gas recirculation and clean it if necessary --
Draining coolant
Replace the fuel-burner glow plug
Check the water pump (visual check) --
Replace the coolant thermostat --
Replace the radiator cap --
All steps for maintenance once a day and once a week (and all steps for maintenance at 500 and 1000 oper-
ating hours)
--

Table of Contents