2.22 Engine power correction factors
Performance
data
conditions
Performance data on John Deere engines are measured at the following standard
conditions:
744 mm (29.31 in.) of mercury dry air pressure
183 m (600 ft.) altitude
0% relative humidity
25°C (77°F) air intake temperature
40°C (104°F) fuel inlet temperature
Refer to the table below to estimate the engine power decrease in percent as
environmental factors vary from the standard conditions.
Engine power
correction
factors
Model
Fuel temp
rise of 1°C
(1.8°F)
Air temp
rise of -12°C
(10°F)
Altitude
rise of 305 m
(1000 ft)
above 3050 m
(10,000 ft)
Relative
humidity rise
of 10%
Altitude
rise of 305 m
(1000 ft)
below 3050 m
(10,000 ft)
G 150
G 180
None
(ECU
compensated)
0.50 4.00 0.07 0.5
G 240 None
(ECU
compensated)
None
(ECU
compensated)
5.00 0.07 None
(ECU
compensated)