2.23 Racor® Filter
Location
The Racor crankcase filter (a) is located next to the engine.
Description
The crankcase filter removes oil from engine blow-by. Coalesced oil drains into the
engine oil pan. Filtered air is then routed to the engine intake system.
The crankcase filter contains a high-performance element which should be
replaced after every 750 hours of operation. See Replacing the Racor Filter
Element in the Maintenance chapter.
Filter heater
Your crankcase filter may be equipped with a thermostatically controlled heating
system as shown in the illustration on the right. This system prevents water vapor
from condensing and freezing on the inner walls of the filter intake hose while
operating the generator in extremely cold weather.
2.24 Shutting off the generator
Before
shutdown
Check with other personnel on the jobsite and let them know that power is being
turned off. Make sure that the power shutdown will not create any hazards by
turning off devices such as pumps, heaters, or lights that may need to be kept on.
Shutdown
procedure
To shut down the generator:
1. Remove all loads from generator.
2. Open (turn to off “O”) main line circuit breaker.
3. Let engine run for approximately 5 minutes to allow it to cool down.
4. Move Engine Start Switch to the off “O” position.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson G 150 and is the answer not in the manual?

Wacker Neuson G 150 Specifications

General IconGeneral
BrandWacker Neuson
ModelG 150
CategoryPortable Generator
LanguageEnglish

Related product manuals