Specialized Concentrated Focused
Driver「109」
calculation as below:
N1 / M = 40000×4×0.001/5 = 32/1, N1=32,
M=1;
When the multi-electronic gear ratio is not
used, P2-60 ~P2-62 are not required.
Function setting
for digital input
pin DI1
X1X0=01: digital input (DI1 = SON)
corresponds to 9
th
pin of CN1.
X2=1: set DI1 input as NO (normally open)
a-contact point.
Function setting
for digital input
pin DI6
Default factory setting of DI6 and DI7 is NC
(normally closed) limit signal input; driver can‟t
run without being connected to pin 32 and pin
31 of CN1.
X2=1: set DI6 and DI7 input as NO a-contact
points.
X1X0=00, limit input of the driver is not used.
Function setting
for digital input
pin DI7
Function setting
for digital input
pin DI8
External EMG stop input is not used.
Function setting
for digital output
pin DO1
DO1 corresponds to pin 6 & pin 7, used as
clamping-position brake signal of Z-axis;
X2=1: set DO1 output as NO (normally open)
a-contact point; X2=0: set DO1 output as NC
(normally closed) b-contact point;
X1X0=08: set pin 6 and pin 7 as BK- and BK+
respectively.
Function setting
for digital output
pin DO5
DO5 corresponds to pin 28 & pin 27, used as
servo alarm signal.
X2=0: set DO5 output as NC b-contact point.
X1X0=07: set pin 28 and pin 27 as ALRM+
and ALRM- respectively.