Operation33
3.5 Spindle Parameters Adjustment
3.5.1 Spindle Speed Setting
Users can directly set spindle speed on the system interface.
In auto mode, press SF1 to enter [Auto] function section, as shown in Fig. 3-15.
Fig. 3-15 Auto Function Section
Users can directly set the spindle speed in the parameters setting region above the manipulation button
bar, shown in Fig. 3-16. When the parameter Use default spindle speed” is set as “True”, spindle speed
will adopt the value set in the system during auto processing, i.e. the value of “Spindle speed”; when set
as “False”, spindle speed will adopt the value specified in the processing program.
Fig. 3-16 Parameters Setting Region-spindle Speed Setting
Press “→” “←” shift key to move to the corresponding parameter setting box, and then press Enter key to
input the value into the pop-up parameter input box.
Spindle speed is controlled by adjusting current spindle override. The formula is as below:
Current Spindle Speed Spindle Speed Current Spindle Override
Spindle override selection button is on the operation panel, shown in Fig. 3-17.