Specialized Concentrated Focused
「42」Operation
3) Repeat the above operation to each tool.
Related parameter
It specifies the height between tool sensor and work
table.
When there is no tool sensor, please move the tool manually to the workpiece surface and press F4
under [Tool Cali] interface, the current Z-axis machine coordinate recorded in tool offset directly. After
that, users can check the set tool offset in [Tool View Table] under [Parameter] function section, shown
as below:
Fig. 3-26 Tool View Table
3.7.4 First Presetting/ Second Presetting
The operation steps are as below:
Firstly, manually move Z axis to workpiece surface, and then confirm the workpiece origin by floating
presetting or manual clear (the method for manual clear: press F1 [Clear], and then press F3 [Z
Clear] in the new pop-up manipulation button bar).
Secondly, press F6 [Tool Cali], and then press F1 [First Calli] to execute the first calibration in the
new pop-up manipulation button bar, and then the system will record the current workpiece
coordinate value of Z axis automatically, as shown in Fig. 3-27. The system ends this process
automatically.