Specialized Concentrated Focused
「118」Driver
Set rotation direction
of motor
Input positive order, motor rotates
anti-clockwise.
Input positive order, motor rotates
clockwise.
Electronic gear ratio
numerator
The input pulse amount will be multiplied with this
number before output. Ratio range of parameter 21 to
22:
1/127<parameter 21/ parameter 22<127
Electronic gear ratio
denominator
The input pulse amount will be multiplied with this
number before output. Ratio range of parameter 21 to
22:
1/127<parameter 21/ parameter 22<127
Set the value of
Pin20 of CN1
Output of “0” speed signal
Set the maximum
pulse frequency
received by the
driver under position
control mode
It can correct the phenomenon of unauthorized
over-travel. 7 means frequency received is 200Kpps.
For the parameter setting of driver of various brands, refer to the driver manual of specific brand.