6.2.4 Measuring the supply flow pressure
Requirements
A gas shut-of
f device is installed at the customer's premises.
The gas has been installed correctly in accordance with the instructions under 'Installing the gas' on page 53 as far as
the step 'Measuring the supply flow pressure'.
Materials required
pressure meter
Measuring the supply flow pressure
1.
Measure the supply flow pressure at the valve (1) of the gas valve on
the fan burner
.
2.
Compare the measured value with the specified limits; see 'Data for
gas operation' in 'Technical data' on page 74.
Result:
If the measured supply flow pressure is lower than the specified val-
ues:
Notify the gas provider. In this case the appliance must not be
put into use and the gas supply must be switched off.
If the measured supply flow pressure is higher than the specified
values:
Reduce the supply flow pressure.