9.12 Gas specification, Japan
C4 GB/GS
Gas type
Natural gas 13A
(JPN)
Propane (JPN)
Operating materials
Natural gas, Propane x x
Gas supply values
Gas pipe connection R 3/4" R 3/4"
Supply flow pressure [kPa] 2.0 (1.0 - 2.5) 2.8 (2.0 - 3.3)
Gas data (as per CE) at 15 °C and 1013 mbar dry
Wobbe index (Ws) [MJ/m³N] 55.3 (52.7 - 57.8) 84.3
Exhaust gas extraction system
Air ventilation system with safety shutdown mandatory mandatory
Exhaust gas values
Exhaust gas value CO
2
[%] 9.8 - 10.0 10.9 - 11.3
Exhaust gas value CO [ppm] < 500 < 500
9.13 Gas specification, Korea
C4 GB/GS
Gas type
Natural gas 13A
(KOR)
Propane (KOR)
Code LNG LPG
Operating materials
Natural gas, Propane x x
Gas supply values
Gas pipe connection R 3/4" R 3/4"
Supply flow pressure [kPa] 2.0 (1.0 - 2.5) 2.8 (2.0 - 3.3)
Gas data (as per CE) at 15 °C and 1013 mbar dry
Wobbe index (gross)
[MJ/m
3
]
56.1 (52.8 - 57.8) 84.6
Gross caloric value (Hs)
[MJ/m
3
]
44.5 110
Exhaust gas extraction system
Air ventilation system with safety shutdown mandatory mandatory
Exhaust gas values
Exhaust gas value CO
2
[%] 9.3 - 9.5 10.9 - 11.3
Exhaust gas value CO [ppm] < 500 < 500