9.4 Electrical supply, GB/GS
C4 GB (single-phase FC)
12.20 20.10 20.20
1N~ 230V 50/60Hz (1/N/PE)
Rated power consumption [kW] 0.6 1.1 1.1
Convection power [kW] 0.1 0.2 0.2
Steam power [kW] 0.1 0.1 0.1
Motor power [kW] 0.35 0.7 0.7
Rated current [A] 2.7 4.7 4.7
Fuse rating [A] 16 16 16
Residual current [mA] 11.5 - -
Protective earth current [mA] - - -
Recommended conductor cross-section for wires laid uncovered in air up
to 5 m in length.
[mm
2
]
3G2.5 3G2.5 3G2.5
Residual-current device Type A/B A/B A/B
C4 GS (single-phase FC)
12.20 20.10 20.20
1N~ 230V 50/60Hz (1/N/PE)
Rated power consumption [kW] 0.6 1.1 1.1
Convection power [kW] 0.1 0.2 0.2
Motor power [kW] 0.35 0.7 0.7
Rated current [A] 2.3 4.3 4.3
Fuse rating [A] 16 16 16
Residual current [mA] - 11.5 15.0
Protective earth current [mA] - - 91.0
Recommended conductor cross-section for wires laid uncovered in air up
to 5 m in length.
[mm
2
]
3G2.5 3G2.5 3G2.5
Residual-current device Type A/B A/B A/B
9 Technical data
Installation manual 79